65-series Differential pH(P65) and ORP(R65) Sensors

  • Integral two-wire 4-20 mA transmitter can be fed directly to PLC, DCS
  • Accurate differential measurement
  • Eliminates ground loop interference
  • Built-in pre-amp supports up to 3,000' sensor-to-analyzer distance
  • 15 ft. (5m) standard cable length
  • Replaceable saltbridge for extended service life
  • Flow-thru, Hot-tap or submersible mounting
  • Automatic temperature compensation on pH versions
  • Semi-flush face available: reduced buildup
  • Long-lasting
  • Low Maintenance Cost
  • Field-proven

P/R60C-4 Insertion Style, Differential pH/ORP Sensors

  • 1.5" NPT fixed threads
  • Accurate differential measurement
  • Eliminates ground loop interference
  • Built-in pre-amp supports up to 3,000' sensor-to-analyzer distance
  • 15 ft. (5m) standard cable length
  • Replaceable saltbridge for extended service life
  • Flow-thru mounting
  • With temperature compensation device
  • 2 year warranty

P/R60C-6 Variable Insertion, Differential pH/ORP Sensors

  • Now with larger electrode and ground rod for better signal-to-noise and faster response
  • 1.25" NPT CPVC compression fitting
  • Accurate differential measurement
  • Eliminates ground loop interference
  • Built-in pre-amp supports up to 3,000' sensor-to-analyzer distance
  • 15 ft. (5m) standard cable length
  • Replaceable saltbridge for extended service life
  • Flow-thru or submersible mounting
  • With temperature compensation device
  • Extended body option available for ball valve assembly (P/R60C-7)

P/R60R-8 Fixed Insertion Differential pH/ORP Sensors

The P60R-8 pH and the R60R-8 ORP probes are dependable industrial grade sensors designed to provide accurate measurement and longer service life under the most demanding conditions.

  • 1.5" NPT fixed threads on both ends of sensor
  • Accurate differential measurement
  • Eliminates ground loop interference
  • Built-in pre-amp supports up to 3,000' sensor-to-analyzer distance
  • 15 ft. (5m) standard cable length
  • Replaceable saltbridge for extended service life
  • Flow-thru or submersible mounting

2200C Conductivity Controller

  • Simple step-through menu design for quick and easy setup
  • On/Off cycle timer feature
  • High/low alarm relay
  • ALARM LED on front panel
  • Output signal field-scalable for maximum resolution
  • Status errors illuminate FAIL LED on front panel
  • Test feature allows sweep through range to test setpoints and alarms or to simulate value for setup
  • Auto temperature compensation
  • Password protection
  • High temperature/pressure and low temperature/pressure cells available

2200R ORP Analyzer/Controller

  • Simple step-through menu design for quick & easy setup
  • Bidirectional control through two control relays with independent setpoints for Relay On and Relay Off
  • Cycle-Time option minimizes chemical overshoot
  • High/low alarm relay
  • ALARM LED on front panel
  • Accepts R60 Series differential ORP probes with replaceable salt bridge or standard combination ORP probes
  • Output signal is field-scalable for maximum resolution
  • STATUS errors illuminate LED on front panel

2200P pH Analyzer/Controller

  • Simple step-through menu design for quick & easy setup
  • Bidirectional control through two control relays with independent setpoints for Relay On and Relay Off
  • Cycle-Time option minimizes chemical overshoot
  • High/low alarm relay
  • ALARM LED on front panel
  • Accepts P60 Series differential pH probes with replaceable salt bridge or standard combination pH probes
  • Output signal is field-scalable for maximum resolution
  • Automatic buffer recognition
  • STATUS errors illuminate LED on front panel

SHARK TXP Transmitters

  • For pH, ORP, Conductivity/Resistivity and Flow
  • 1/4 DIN, NEMA 4X front panel, Polycarbonate Enclosure
  • 24 VDC / 24 VDC Loop
  • Easy to read 2 X 16 character LCD display
  • Quick and easy to calibrate
  • Single 4-20mA output with range expandability
  • Operates with most Water Analytics sensors
  • Panel and DIN rail mounting only

SHARK TX Transmitters

  • For pH, ORP, Conductivity/Resistivity and Flow
  • 1/4 DIN, NEMA 4X, Polycarbonate Enclosure
  • 24 VDC / 24 VDC Loop
  • Easy to read 2 X 16 character LCD display
  • Quick and easy to calibrate
  • Single 4-20mA output with range expandability
  • Operates with most Water Analytics sensors
  • Universal mounting hardware provided for surface, panel & pipe mounting

Shark-120/240 Controllers

NOTE: The Shark-120 and Shark-240 are now both replaced by the 2250. We will continue to service existing Shark controllers and will sell them until supplies run out. Call for more information.

Syndicate content